Utzschneider K. M., Prigeon R. L., Tong J., Gerchman F., Carr D. B., Zraika S., Udayasankar J., Montgomery B., Mari A., Kahn S. E. Within-subject variability of measures of beta cell function derived from a 2 h OGTT: implications for research studies. In: Diabetologia, vol. 50 (12) pp. 2516 - 25. Springer, 2007.
 
 
Abstract
(English)
AIMS/HYPOTHESIS: Knowledge of the within-subject variability of a parameter is required to properly design and calculate sample sizes for longitudinal studies. We sought to determine the day-to-day variability of measures of beta cell function derived from an OGTT. METHODS: Thirty-seven adults (13 with normal glucose tolerance, ten with impaired glucose tolerance, 14 with type 2 diabetes) underwent a standard 2 h 75 g OGTT on two separate days (median time between tests, 7 days; range, 5-14). From these data, the reproducibility of several indices of beta cell function were determined: insulinogenic index (DeltaI(0-30)/DeltaG(0-30)), early C-peptide response (DeltaCP(0-30)/DeltaG(0-30)), incremental AUC insulin to glucose response (incAUC(ins)/incAUC(glu)), integrated insulin secretion response from 0 to 120 min (IS/Glu(0-120)) and indices of beta cell function derived from a mathematical model. RESULTS: Within-subject variability for DeltaI(0-30)/DeltaG(0-30) (CV 57.1%) was higher than DeltaCP(0-30)/DeltaG(0-30) (CV 34.7%). Measures integrated over the full 120 min of the OGTT, incAUC(ins)/incAUC(glu) (CV 24.9%) and IS/Glu(0-120) (CV 17.4%), demonstrated less variability. The mathematical model-derived measures of beta cell glucose sensitivity (CV 20.3%) and potentiation (CV 33.0%) showed moderate variability. The impact of the different measures' variability on sample size (30% change from baseline) is demonstrated by calculated sample sizes of 89 for DeltaI(0-30)/DeltaG(0-30), 37 for DeltaCP(0-30)/DeltaG(0-30), 21 for incAUC(ins)/incAUC(glu) and 11 for IS/Glu(0-120). CONCLUSIONS/INTERPRETATION: Some OGTT-derived indices of beta cell function, in particular the insulinogenic index, demonstrate high within-subject variability. Integrated measures that utilise multiple time points and measures that use C-peptide show less variability and may lead to a reduced sample size requirement.
URL: http://www.ncbi.nlm.nih.gov/pubmed/17928990?dopt=Citation
DOI: 10.1007/s00125-007-0819-5
Subject beta-cell function
Insulin secretion
insulin sensitivity
insulinogenic index
reproducibility


Icona documento 1) Download Document PDF


Icona documento Open access Icona documento Restricted Icona documento Private

 


Per ulteriori informazioni, contattare: Librarian http://puma.isti.cnr.it

Valid HTML 4.0 Transitional